2026-09-18 19:45:24 +08:00
..

DC3 Driver DLT645

Overview

dc3-driver-dlt645 is the DL/T 645-2007 smart electricity meter driver of the IoT DC3 platform. It communicates with meters over a serial port (RS485) using the jSerialComm library, caching one serial connection per meter. Each point reads a data identifier (DI0-DI3) from the meter and decodes the response data field (offset by +0x33 per the standard) according to a configurable data format.

Module Information

  • Group ID: io.github.pnoker
  • Artifact ID: dc3-driver-dlt645
  • Driver Name: DL/T 645 Driver

Driver Attributes (Device-level)

Attribute Code Type Default Description
Serial Port port STRING /dev/ttyUSB0 Serial port device path
Baud Rate baudRate INT 2400 Baud rate (1200, 2400, 4800, 9600)
Data Bits dataBits INT 8 Data bits (7, 8)
Stop Bits stopBits INT 1 Stop bits (1, 2)
Parity parity INT 2 Parity (0=None, 1=Odd, 2=Even)
Timeout timeout INT 1000 Read timeout in milliseconds
Meter Address meterAddress STRING 000000000000 12-digit meter address in BCD
Write Password password STRING 00000000 8-char hexadecimal write password (4 bytes)
Operator Code operatorCode STRING 00000000 8-char hexadecimal operator code (4 bytes)

Point Attributes

Attribute Code Type Default Description
Data Identifier di STRING 00010000 8-char hexadecimal DI0-DI3 (00010000 = total active energy)
Data Format dataFormat STRING HEX Data format: HEX, BCD, INT, FLOAT, ASCII

Command Attributes (write)

Attribute Code Type Default Description
Data Identifier di STRING 00010000 8-char hexadecimal DI0-DI3
Data Format dataFormat STRING HEX Format used to encode the written value

The module application.yml is authoritative for attribute codes, types, defaults, scheduling, health, and local buffering. Keep this README aligned when those user-facing settings change.

Prerequisites

A DL/T 645-2007 electricity meter connected over RS485 to a serial port reachable from the host running the driver (e.g. /dev/ttyUSB0), with baud rate, parity (typically even), and the 12-digit meter address configured.

Running Locally

make up-db
make up-dev GROUP=core
mvn -s .mvn/settings.xml -pl dc3-driver/dc3-driver-dlt645 -am package
java -jar dc3-driver/dc3-driver-dlt645/target/dc3-driver-dlt645.jar

Testing

mvn -s .mvn/settings.xml -pl dc3-driver/dc3-driver-dlt645 -am test
  • dc3-common-driver — Driver SDK for registration, scheduling, and RabbitMQ integration